AP 500

Product: PERKINS Alternator: ECO 40-3S/4 C Regelsystemen: DSE 7320
Over Product
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
Certificaten
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
Algemene kenmerken
Modelnaam AP 500
Frequentie (HZ) 50
Brandstoftype Diesel
Motormerk en -model PERKINS - 2506A-E15TAG1
Alternatormerk en -model Mecc Alte - ECO 40-3S/4 C
Configuratiescherm Model DSE 7320
Cabine MS 80
3 Fasen, 50 Hz, PF 0.8
Spanning Stand-by vermogen (ESP) Prime Power (PRP) Standby Amper
kVA kW kVA kW
400/231 500 400.0 455 364.0 721.71
Stand-by vermogen (ESP) : Het wordt gebruikt om te voldoen aan de variabele elektrische belastingvereiste in geval van uitval van de betrouwbare netvoeding. ESP voldoet aan ISO 8528-1 Overbelasting is niet toegestaan.

Prime Power (PRP) : Wordt gedefinieerd als het continue bedrijfsvermogen onder variabele belasting. PRP voldoet aan ISO 8528-1 10% overbelasting kan elke 12 uur worden gedaan.
Motorkenmerken
Motor PERKINS
Motor model 2506A-E15TAG1
Aantal Cilinders En Gebouw 6 cylinders - in line
Boor En Slag mm 137 X 171
Totale Verplaatsing L 15.2
Aspiratie Turbo Charged and Charge Air Cooled
Compressieverhouding 16.0:1
Nominale snelheid d/dk 1500
Olie capaciteit L 62
Stand-by vermogen (kW/HP) 451/604,55
Prime Power (kW/HP) 412/552,27
Blokverwarmingshoeveelheid
1
Blokkeer verwarmingsvermogen (Watt) 3000
Brandstoftype
Diesel
Injectietype en systeem
Direct
Type brandstofpomp
MEUI
Governor-systeem
ECM
Bedrijfsspanning (Vdc)
24 Vdc
Batterij en capaciteit (aantal / Ah) 2x120
Laaddynamo (A)
70
Koelmethode
Water Cooled
Koelventilatorluchtstroom (m³ / min) 722
Koelvloeistofcapaciteit (alleen motor / met radiator) (lt) /58
Luchtfilter
Dry Type
Brandstofverbruik bij eerste 100% belasting (lt / uur) 95
Brandstofverbruik primair 75% belasting (lt / uur) 72
Brandstofverbruik bij eerste 50% belasting (lt / uur) 50
Dynamo specificaties
Fabrikant Mecc Alte
Alternatormerk en -model ECO 40-3S/4 C
Frequentie (HZ) Hz 50
Kracht (kVA) kVA 500
Ontwerp   4 Pole,  Brushless
Spanning V 400
Fase 3
Automatische spanningsregelaar DER1
Voltage regulatie (+/-) 0.5%
Isolatiesysteem H
Bescherming IP23
Nominale vermogensfactor 0.8
Gewicht dynamo (Kg) 1534
Koellucht (m³/min) m3 54
Grootte en gewicht
Open Type Droog gewicht (kg.)
(kg.)
Lengte
(mm.)
Breedte
(mm.)
Hoogte
(mm.)
Inhoud brandstoftank (lt.) (Lt.)
3650 3248 1550 2103 850
Cabin Group Droog gewicht (kg.)
(kg.)
Lengte
(mm.)
Breedte
(mm.)
Hoogte
(mm.)
Inhoud brandstoftank (lt.) (Lt.)
MS 80
4800 4807 1606 2485 850
Standaardfuncties
Water cooled, Diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Base frame design incorporates an integral fuel tank and anti-vibration isolators 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately(for open sets) 
Static battery charger 
Manual for application and installation
Generator hardware-opties
ENGINE
Fuel-Water Seperator Filter 
Oil heater 
ALTERNATOR
Anti-Condensation Heater 
Over sized alternator 
Main line circuit breaker 
CONTROL SYSTEM
Remote annunciator panel 
Remote relay output 
Alarm output relays 
Remote communication with modem 
Earth fault, single set 
Charge Ammeter 
TRANSFER SWITCH
Three or four pole contactor 
Three or four pole motor operated circuit breaker 
OTHER ACCESSORIES
Main Fuel Tank 
Automatic or manual fuel filling system 
Manual oil drain pump 
Electrical oil drain pump 
Residential silencer 
Enclosure: weater protective or sound attenuated 
Duct adapter ( on radiator) 
Inlet and outlet motorised louvers 
Inlet and outlet acoustic baffles 
Trailer Tool kit for maintenance 
Supplied with oil and coolant - 30 °C 
Battery isolating switch
Regelsystemen: DSE 7320
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
Apparaten
DSE, model 7320 Auto Mains Failure control module Static battery charger Emergency stop push button and fuses for control circuits
Structuur en verf
Comonents installed in sheet steel enclosure.
Phosphate chemical, pre-coating of steel provides corrosion resistant surface
Polyester composite powder topcoat forms high gloss and extremely durable finish
Lockable hinged panel door provides for easy component access
Montage
Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating set with properly panel visibility.
Generator regeleenheid
The DSE 7320 conrol module is a standard addition to our generator sets from 220 kVA upwards and it has been designed to start and stop diesel andgas generating sets that include electronic and non electronic engines.
The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable for controlling a standby generating set in conjunction with an automatic transfer switch.
The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and indicating faults by means of its LCD display on the front panel.

Standaardfuncties
Microprocessor controlled
- 132 x 64 pixel LCD display makes information easy to read
- Front panel programming and also via PC software
- Soft touch membrane keypad and five key menu navigation
- Remote communications via RS232, RS485 and ethernet.
- Event logging (50) showing date and time
- Multiple date and time engine exercise mode and maintenance scheduler
- Engine block heater control.
- Controls; stop, manuel, auto, test, start, mute lamb test/transfer to generator, transfer to mains, menu navigation.

Meetindicatoren
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time Battery volts
Engine maintenance due

GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
Earth current
kW
Pf
kVAr
kWh, kVAh, kVArh
Phase sequence

MAINS
Voltage (L-L, L-N)
Frequency
Beveiligingscircuits
WARNING
Charge failure
Battery under voltage
Fail to stop
Low fuel level (opt.)
kW over load
Negative phase sequence
Loss of speed signal

PRE-ALARMS
Low oil pressure
High engine temperature
Low engine temperature
Over /Under speed
Under/over generator frequency
Under/over generator voltage
ECU warning

SHUT DOWNS
Fail to start
Emergency stop
Low oil pressure
High engine temperature
Low coolant level
Over /Under speed
Under/over generator frequency
Under/over generator voltage
Oil pressure sensor open
Phase rotation

ELECTRICAL TRIP
Earth fault
kW over load
Generator over current
Negative phase sequence


Optie Kenmerken
High oil temperature shut down
Low fuel level shut down
Low fuel level alarm
High fuel level alarm

EXPANSION MODULES
Editional LED module (2548)
Expension relay module (2157)
Expansion input module (2130)
Standaarden
Elecrical Safety / EMC compatibility

BS EN 60950 Electrical business equipment
BS EN 61000-6-2 EMC immunity standard
BS EN 61000-6-4 EMC emission standard
Elektronische acculader
Battery charger is manufactured with switching-mode and SMD technology and it has high efficincy.
Battery charger models' output V-I characteristic is very close to square
2405 has fully output shot circuit protection and ıt can be used as a current source.
2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives.
The charger is fitted with a protection diode across the output.
Charge fail output is available.
Connect charge fail relay coil between positive output and CF output.
Input: 196-264V.
Output: 27,6V 5A or 13,8V 5A.
Cabine: MS 80
1. Steel structures. 
2. Emergency stop push button. 
3. Control panel is mounted on the baseframe . Located at the right side of the generator set. 
4. Corrosion-resistant locks and hinges. 
5. Oil could be drained via valve and a hose 
6. Exhaust system in the canopy. 
7. Special large access doors for easy maintanance 
8. In front and back side special large access doors for easy maintanance 
9. Base frame -fuel tank. 
10. Lifting points similar to ISO container , located on each top corner of the canopy. 
11. The cap on the canopy provides easy accsess to radiator cap. 
12. Sound proofing materials 
13. Plastic air intake pockets.
Over Product
Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
Standaardfuncties
Compact footprint, low profile design. 
Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package 
Body made from steel components treated with polyester powder coating 
Fire retardant foam insulation 
Easy access to all service points 
Exhaust system inside canopy 
Large doors on each side 
Control panel viewing window in a lockable access door 
Emergency stop push button mounted on enclosure exterior 
Cooling fan and battery charging alternator fully guarded 
Fuel fill and battery can only be reached via lockable access doors. 
Lifting points on the top of canopy and base frame 
Customer options available to meet your applications needs. 
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been aproved by the notified body Szutest

Kastserie Model MS 80
Breedte mm. 1606
Lengte mm. 4807
Hoogte mm. 2485
Inhoud brandstoftank (lt.) Lt. 850