APD 75 A

PRODUCTOS : AKSA alternador: AK 360 Sistema de Control: DSE 6120
Acerca del producto

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

CERTIFICADOS
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
CARACTERISTICAS GENERALES
Model Name APD 75 A
Frecuencia (Hz) 50
Tipo de combustible Diesel
Marca y modelo del motor AKSA - A4CRX36TI
Alternador hechas en el modelo Aksa - AK 360
Sistema de Control DSE 6120
Cubierta ACP 5
3 fase, 50 Hz, PF 0.8
Voltaje (AC) Potencia en espera Potencia principal Standby Amper
kVA kW kVA kW
400/231 75 60.00 70 56.00 108.26
Potencia en espera : Si interrumpido la alimentación de la red confiable, se utiliza para suministrar potencia a la variable carga eléctrica. ESP es conforme a ISO8528. No se permite la sobrecarga.

Potencia principal : Se utiliza por un tiempo indefinido a lo largo de un año, con el fin de suministrar potencia a la variable carga eléctrica. PRP es conforme a ISO 8528. Se usa para sobrecarga de 10% por una hora, en 12 horas de trabajo.
especificaciones de motor
Motor AKSA
Modelo de motor A4CRX36TI
Nº de cilindros 4 cylinders - in line
Calibre x Carrera mm 98 X 120
Desplazamiento L 3.6
Aspiración Turbo Charged
Relación de compresión 17.5:1
Velocidad nominal (rpm) d/dk 1500
Capacidad de aceite (L) L 10
Potencia en espera (kW/HP) 67/89.8
Potencia primaria  (kW/HP) 63/84.5
Cabecera del bloque QTY
1
Potencia de la cabecera del bloque (Watt) 500
Tipo de combustible
Diesel
Tipo y sistema de inyección
Direct
Tipo de bomba de combustible
6BB pump
sistema de regulación
Mechanic
Tensión de funcionamiento (Vdc)
12 Vdc
La batería y la capacidad (Cant / Ah) 1x54
 Método de refrigeración
Water Cooled
 Flujo de aire de ventilador de refrigeración (m³/min) 175.2
Coolant Capacity (engine only / with radiator) (lt) 5/19.5
Filtro de aire
Dry Type
Fuel Cons. Prime con 100% Carga (lt/hr) 17.25
especificaciones de alternador
Manufacturer Aksa
Alternador hechas en el modelo AK 360
Frecuencia (Hz) Hz 50
Potencia (kVA) kVA 75
Diseño   4 Pole,  Brushless
Voltaje (AC) V 400
fase 3
Regulador automático de tensión SX460
Regulación de tensión (+/-) 1.5%
Sistema de aislamiento H
Proteccion IP22
Factor de potencia 0.8
peso generador completo (Kg.) 337
El aire de refrigeración m3 12,96
Tamaño y peso
De tipo abierto Peso seco (Kg)
(kg.)
Longitud (mm)
(mm.)
Anchura (mm)
(mm.)
Altura (mm)
(mm.)
Capacidad del tanque (L) (Lt.)
- - - -
Cubierta Peso seco (Kg)
(kg.)
Longitud (mm)
(mm.)
Anchura (mm)
(mm.)
Altura (mm)
(mm.)
Capacidad del tanque (L) (Lt.)
ACP 5
1250 2282 1008 1532 180
Especificación estándar
Heavy duty, water cooled diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Steel base frame and anti-vibration isolators 
Spare external fuel tank (open set) 
Flexible fuel connection hoses 
Two bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately 
Static battery charger 
Manual for application and installation 
EQUIPOS OPCIONALES
ENGINE
  • Remote Radiator Cooling
  • Fuel-Water Seperator Filter
  • Oil heater
ALTERNATOR
  • Anti-Condensation Heater
  • Main line circuit breaker
CONTROL SYSTEM
  • Charge Ammeter
TRANSFER SWITCH
  • Three Pole Contactor
  • Four Pole Contactor
  • Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
  • Main Fuel Tank
  • Automatic or manual fuel filling system
  • Manual oil drain pump
  • Low and high fuel level alarm
  • Residential silencer
  • Enclosure: weater protective or sound attenuated
  • Trailer
  • Tool kit for maintenance
Sistema de Control: DSE 6120
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
Devices
●DSE, model 6120 Auto Mains Failure control module.
●Battery charger input 198-264 volt, output 27,6 V 5 A (24 V) or 13,8 Volt 5A (12V)
●Emergency stop push button and fuses for control circuits.
CONSTRUCTION and FINISH
●Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface. Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable and hinged panel door provides easy access to components.
INSTALLATION
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at the Gen.Set. from Alternator)
GENERATING SET CONTROL UNIT
The DSE 6120 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant temperature running hours and battery volts.
Module monitors the mains supply and switch over to the generator when the mains power fails.
The DSE6120 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving true first up fault condition of Gen. Set failure.The LCD display indicates the fault.

Especificación estándar
●Microprocessor controlled.
●LCD display makes information easy to read.
●Automatically transfers between mains (utilty) and generator power.
●Manual programming on front panel.
●User-friendly set-up and button layout.
●Remote start.
●Event logging (50) showing date and time.
●Controls: Stop/Reset, Manual, Auto, Test, Start, buttons. An additional push button next to the LCD display is used to scroll through the modules' metering displays.

instrumentos
ENGINE
●Engine speed.
●Oil pressure.
●Coolant temperature.
●Run time.
●Battery volts.
●Configurable timing.

GENERATOR
●Voltage (L-L, L-N).
●Current (L1-L2-L3).
●Frequency.
●Gen. Set ready.
●Gen. Set enabled.

MAINS
●Mains ready.
●Mains enabled.
Circuitos de protección
WARNING 
●Charge failure. 
●Battery Low/High voltage. 
●Fail to stop. 
●Low /High generator voltage. 
●Under /Over generator frequency. 
●Over /Under speed. 
●Low oil pressure. 
●High coolant temperature. 

SHUT DOWNS 
●Fail to start.
●Emergency stop. 
●Low oil pressure. 
●High coolant temperature. 
●Over /Under speed. 
●Under/over generator frequency. 
●Under/over generator voltage. 
●Oil pressure sensor open. 
●Coolant temperature sensor open. 

ELECTRICAL TRIP 
●Generator over current.


Opciones
●Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
●Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
Estándares
●Elecrical Safety / EMC compatibility
●BS EN 60950 Electrical business equipment.
●BS EN 61000-6-2 EMC immunity standard.
●BS EN 61000-6-4 EMC emission standard
Cargador de batería estático
● Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
● Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC.
● The charger is fitted with a protection diode across the output.
● Connect charge fail relay coil between positive output and CF output.
● They are equipped with RFI filter to reduce electrical noise radiated from the device.
● Galvanically isolated input and output typically 4kV for high reliability.
Cubierta: ACP 5
Acerca del producto
Sound–attenuated and Weather-protective Enclosures Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
Especificación estándar


Modelo de cubierta ACP 5
Anchura (mm) mm. 1008
Longitud (mm) mm. 2282
Altura (mm) mm. 1532
Capacidad del tanque (L) Lt. 180