APD 75 A
PRODUCTOS
: AKSA
alternador: AK 360
Sistema de Control: DSE 6120

Acerca del producto
CERTIFICADOS
CARACTERISTICAS GENERALES
3 fase, 50 Hz, PF 0.8
especificaciones de motor
especificaciones de alternador
Tamaño y peso
Especificación estándar
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
TS ISO 8528
TS ISO 9001-2008
CE
SZUTEST
2000/14/EC
Model Name |
APD 75 A |
||
---|---|---|---|
Frecuencia (Hz) |
50 |
||
Tipo de combustible |
Diesel |
||
Marca y modelo del motor |
AKSA - A4CRX36TI |
||
Alternador hechas en el modelo |
Aksa - AK 360 |
||
Sistema de Control |
DSE 6120 |
||
Cubierta | ACP 5 |
Voltaje (AC) | Potencia en espera | Potencia principal | Standby Amper | ||
---|---|---|---|---|---|
kVA | kW | kVA | kW | ||
400/231 | 75 | 60.00 | 70 | 56.00 | 108.26 |
Potencia en espera : Si interrumpido la alimentación de la red confiable, se utiliza para suministrar potencia a la variable carga eléctrica. ESP es conforme a ISO8528. No se permite la sobrecarga.
Potencia principal : Se utiliza por un tiempo indefinido a lo largo de un año, con el fin de suministrar potencia a la variable carga eléctrica. PRP es conforme a ISO 8528. Se usa para sobrecarga de 10% por una hora, en 12 horas de trabajo.
Potencia principal : Se utiliza por un tiempo indefinido a lo largo de un año, con el fin de suministrar potencia a la variable carga eléctrica. PRP es conforme a ISO 8528. Se usa para sobrecarga de 10% por una hora, en 12 horas de trabajo.
Motor |
AKSA |
||
---|---|---|---|
Modelo de motor | A4CRX36TI | ||
Nº de cilindros | 4 cylinders - in line | ||
Calibre x Carrera | mm | 98 X 120 | |
Desplazamiento | L | 3.6 | |
Aspiración | Turbo Charged | ||
Relación de compresión | 17.5:1 | ||
Velocidad nominal (rpm) | d/dk | 1500 | |
Capacidad de aceite (L) | L | 10 | |
Potencia en espera (kW/HP) | 67/89.8 | ||
Potencia primaria (kW/HP) | 63/84.5 | ||
Cabecera del bloque QTY | |||
1 | |||
Potencia de la cabecera del bloque (Watt) | 500 | ||
Tipo de combustible | |||
Diesel | |||
Tipo y sistema de inyección | |||
Direct | |||
Tipo de bomba de combustible | |||
6BB pump | |||
sistema de regulación | |||
Mechanic | |||
Tensión de funcionamiento (Vdc) | |||
12 Vdc | |||
La batería y la capacidad (Cant / Ah) | 1x54 | ||
Método de refrigeración | |||
Water Cooled | |||
Flujo de aire de ventilador de refrigeración (m³/min) | 175.2 | ||
Coolant Capacity (engine only / with radiator) (lt) | 5/19.5 | ||
Filtro de aire | |||
Dry Type | |||
Fuel Cons. Prime con 100% Carga (lt/hr) | 17.25 |
Manufacturer | Aksa | |
---|---|---|
Alternador hechas en el modelo | AK 360 | |
Frecuencia (Hz) | Hz | 50 |
Potencia (kVA) | kVA | 75 |
Diseño | 4 Pole, Brushless | |
Voltaje (AC) | V | 400 |
fase | 3 | |
Regulador automático de tensión | SX460 | |
Regulación de tensión | (+/-) | 1.5% |
Sistema de aislamiento | H | |
Proteccion | IP22 | |
Factor de potencia | 0.8 | |
peso generador completo (Kg.) | 337 | |
El aire de refrigeración | m3 | 12,96 |
De tipo abierto | Peso seco (Kg) (kg.) |
Longitud (mm) (mm.) |
Anchura (mm) (mm.) |
Altura (mm) (mm.) |
Capacidad del tanque (L) (Lt.) |
---|---|---|---|---|---|
- | - | - | - | ||
Cubierta | Peso seco (Kg) (kg.) |
Longitud (mm) (mm.) |
Anchura (mm) (mm.) |
Altura (mm) (mm.) |
Capacidad del tanque (L) (Lt.) |
ACP 5![]() |
1250 | 2282 | 1008 | 1532 | 180 |
Heavy duty, water cooled diesel engine
Radiator with mechanical fan
Protective grille for rotating and hot parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine coolant heater
Steel base frame and anti-vibration isolators
Spare external fuel tank (open set)
Flexible fuel connection hoses
Two bearing, class H alternator
Industrial exhaust silencer and steel bellows supplied separately
Static battery charger
Manual for application and installation
EQUIPOS OPCIONALES
Radiator with mechanical fan
Protective grille for rotating and hot parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine coolant heater
Steel base frame and anti-vibration isolators
Spare external fuel tank (open set)
Flexible fuel connection hoses
Two bearing, class H alternator
Industrial exhaust silencer and steel bellows supplied separately
Static battery charger
Manual for application and installation
ENGINE
- Remote Radiator Cooling
- Fuel-Water Seperator Filter
- Oil heater
- Anti-Condensation Heater
- Main line circuit breaker
- Charge Ammeter
- Three Pole Contactor
- Four Pole Contactor
- Three or four pole motor operated circuit breaker
- Main Fuel Tank
- Automatic or manual fuel filling system
- Manual oil drain pump
- Low and high fuel level alarm
- Residential silencer
- Enclosure: weater protective or sound attenuated
- Trailer
- Tool kit for maintenance
Sistema de Control: DSE 6120

1. Menu navigation buttons
2. Close mains button
3. Main Status and instrumentation display
4. Alarm LED's
5. Close generator button
6. Status LED's
7. Operation selecting buttons
2. Close mains button
3. Main Status and instrumentation display
4. Alarm LED's
5. Close generator button
6. Status LED's
7. Operation selecting buttons
Devices
●DSE, model 6120 Auto Mains Failure control module.
●Battery charger input 198-264 volt, output 27,6 V 5 A (24 V) or 13,8 Volt 5A (12V)
●Emergency stop push button and fuses for control circuits.
CONSTRUCTION and FINISH
●Battery charger input 198-264 volt, output 27,6 V 5 A (24 V) or 13,8 Volt 5A (12V)
●Emergency stop push button and fuses for control circuits.
●Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface. Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable and hinged panel door provides easy access to components.
INSTALLATION
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at the Gen.Set. from Alternator)
GENERATING SET CONTROL UNIT
The DSE 6120 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant temperature running hours and battery volts.
Module monitors the mains supply and switch over to the generator when the mains power fails.
The DSE6120 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving true first up fault condition of Gen. Set failure.The LCD display indicates the fault.
Especificación estándar
●Microprocessor controlled.
●LCD display makes information easy to read.
●Automatically transfers between mains (utilty) and generator power.
●Manual programming on front panel.
●User-friendly set-up and button layout.
●Remote start.
●Event logging (50) showing date and time.
●Controls: Stop/Reset, Manual, Auto, Test, Start, buttons. An additional push button next to the LCD display is used to scroll through the modules' metering displays.
Cargador de batería estático
Module monitors the mains supply and switch over to the generator when the mains power fails.
The DSE6120 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving true first up fault condition of Gen. Set failure.The LCD display indicates the fault.
Especificación estándar
●Microprocessor controlled.
●LCD display makes information easy to read.
●Automatically transfers between mains (utilty) and generator power.
●Manual programming on front panel.
●User-friendly set-up and button layout.
●Remote start.
●Event logging (50) showing date and time.
●Controls: Stop/Reset, Manual, Auto, Test, Start, buttons. An additional push button next to the LCD display is used to scroll through the modules' metering displays.
instrumentos
ENGINE
●Engine speed.
●Oil pressure.
●Coolant temperature.
●Run time.
●Battery volts.
●Configurable timing.
GENERATOR
●Voltage (L-L, L-N).
●Current (L1-L2-L3).
●Frequency.
●Gen. Set ready.
●Gen. Set enabled.
MAINS
●Mains ready.
●Mains enabled.
ENGINE
●Engine speed.
●Oil pressure.
●Coolant temperature.
●Run time.
●Battery volts.
●Configurable timing.
GENERATOR
●Voltage (L-L, L-N).
●Current (L1-L2-L3).
●Frequency.
●Gen. Set ready.
●Gen. Set enabled.
MAINS
●Mains ready.
●Mains enabled.
Circuitos de protección
WARNING
●Charge failure.
●Battery Low/High voltage.
●Fail to stop.
●Low /High generator voltage.
●Under /Over generator frequency.
●Over /Under speed.
●Low oil pressure.
●High coolant temperature.
SHUT DOWNS
●Fail to start.
●Emergency stop.
●Low oil pressure.
●High coolant temperature.
●Over /Under speed.
●Under/over generator frequency.
●Under/over generator voltage.
●Oil pressure sensor open.
●Coolant temperature sensor open.
ELECTRICAL TRIP
●Generator over current.
WARNING
●Charge failure.
●Battery Low/High voltage.
●Fail to stop.
●Low /High generator voltage.
●Under /Over generator frequency.
●Over /Under speed.
●Low oil pressure.
●High coolant temperature.
SHUT DOWNS
●Fail to start.
●Emergency stop.
●Low oil pressure.
●High coolant temperature.
●Over /Under speed.
●Under/over generator frequency.
●Under/over generator voltage.
●Oil pressure sensor open.
●Coolant temperature sensor open.
ELECTRICAL TRIP
●Generator over current.
Opciones
●Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
●Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
●Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
●Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
Estándares
●Elecrical Safety / EMC compatibility
●BS EN 60950 Electrical business equipment.
●BS EN 61000-6-2 EMC immunity standard.
●BS EN 61000-6-4 EMC emission standard
●Elecrical Safety / EMC compatibility
●BS EN 60950 Electrical business equipment.
●BS EN 61000-6-2 EMC immunity standard.
●BS EN 61000-6-4 EMC emission standard
● Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
● Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC.
● The charger is fitted with a protection diode across the output.
● Connect charge fail relay coil between positive output and CF output.
● They are equipped with RFI filter to reduce electrical noise radiated from the device.
● Galvanically isolated input and output typically 4kV for high reliability.
● Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC.
● The charger is fitted with a protection diode across the output.
● Connect charge fail relay coil between positive output and CF output.
● They are equipped with RFI filter to reduce electrical noise radiated from the device.
● Galvanically isolated input and output typically 4kV for high reliability.
Cubierta: ACP 5

Acerca del producto
Sound–attenuated and Weather-protective Enclosures Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
Especificación estándar
Modelo de cubierta | ACP 5 | |
---|---|---|
Anchura (mm) | mm. | 1008 |
Longitud (mm) | mm. | 2282 |
Altura (mm) | mm. | 1532 |
Capacidad del tanque (L) | Lt. | 180 |