AC 169-6

Product: CUMMINS Alternator: UCI 274 E - 60Hz Regelsystemen: DSE 6020
Over Product
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
 
Certificaten
  TS ISO 8528
  CE
  SZUTEST
  2000/14/EC
Algemene kenmerken
Modelnaam AC 169-6
Frequentie (HZ) 60
Brandstoftype Diesel
Motormerk en -model CUMMINS - 6BTAA 5,9-G6 - 60Hz
Alternatormerk en -model Stamford - UCI 274 E - 60Hz
Configuratiescherm Model DSE 6020
Cabine MS 60
3 Fasen, 60 Hz, PF 0.8
Spanning Stand-by vermogen (ESP) Prime Power (PRP) Standby Amper
kVA kW kVA kW
480/277 169 135.20 154 123.20 203.28
380/220 161 128.80 146 116.80 244.62
208/120 169 135.20 154 123.20 469.11
Stand-by vermogen (ESP) : Het wordt gebruikt om te voldoen aan de variabele elektrische belastingvereiste in geval van uitval van de betrouwbare netvoeding. ESP voldoet aan ISO 8528-1 Overbelasting is niet toegestaan.

Prime Power (PRP) : Wordt gedefinieerd als het continue bedrijfsvermogen onder variabele belasting. PRP voldoet aan ISO 8528-1 10% overbelasting kan elke 12 uur worden gedaan.
Motorkenmerken
Motor CUMMINS
Motor model 6BTAA 5,9-G6 - 60Hz
Aantal Cilinders En Gebouw 6 cylinders - in line
Boor En Slag mm 102 X 120
Totale Verplaatsing L 5.9
Aspiratie Turbo Charged and AfterCooled
Compressieverhouding 16.5:1
Nominale snelheid d/dk 1800
Olie capaciteit L 16.4
Stand-by vermogen (kW/HP) 160/215
Blokverwarmingshoeveelheid
1
Blokkeer verwarmingsvermogen (Watt) 1000
Brandstoftype
Diesel
Injectietype en systeem
Direct
Type brandstofpomp
Bosch Rotary Type
Governor-systeem
Electronic
Bedrijfsspanning (Vdc)
12 Vdc
Batterij en capaciteit (aantal / Ah) 1x85
Laaddynamo (A)
55
Koelmethode
Water Cooled
Koelventilatorluchtstroom (m³ / min) 162
Koelvloeistofcapaciteit (alleen motor / met radiator) (lt) 9.1/21.4
Luchtfilter
Dry Type
Brandstofverbruik bij eerste 100% belasting (lt / uur) 39
Brandstofverbruik primair 75% belasting (lt / uur) 31
Brandstofverbruik bij eerste 50% belasting (lt / uur) 21
Dynamo specificaties
Fabrikant Stamford
Alternatormerk en -model UCI 274 E - 60Hz
Frequentie (HZ) Hz 60
Kracht (kVA) kVA 146
Ontwerp   4 Pole,  Brushless
Spanning V 380
Fase 3
Automatische spanningsregelaar AS440
Voltage regulatie (+/-) 1
Isolatiesysteem H
Nominale vermogensfactor 0.8
Gewicht dynamo (Kg) 492
Koellucht (m³/min) m3 37
Grootte en gewicht
Open Type Droog gewicht (kg.)
(kg.)
Lengte
(mm.)
Breedte
(mm.)
Hoogte
(mm.)
Inhoud brandstoftank (lt.) (Lt.)
2750 1300 1751 470
Cabin Group Droog gewicht (kg.)
(kg.)
Lengte
(mm.)
Breedte
(mm.)
Hoogte
(mm.)
Inhoud brandstoftank (lt.) (Lt.)
MS 60
2240 3934 1356 2156 470
Standaardfuncties
Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Base frame design incorporates an integral fuel tank and anti-vibration isolators Flexible fuel connection hoses Single bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately(for open sets) Static battery charger Manual for application and installation
Generator hardware-opties
TRANSFER SWITCH
- Three or four pole motor operated circuit breaker
- Four Pole Contactor
- Three Pole Contactor
OTHER ACCESSORIES
- Supplied with oil and coolant - 30 °C
- Tool kit for maintenance
- Trailer
- Automatic transfer switch
- Main Fuel Tank
- Battery isolating switch
- Inlet and outlet acoustic baffles
- Low and high fuel level alarm
- Electrical oil drain pump
- Automatic or manual fuel filling system
- Duct adapter ( on radiator)
- Enclosure: weater protective or sound attenuated
- Residential silencer
CONTROL SYSTEM
- Remote communication with modem
- Alarm output relays
- Charge Ammeter
- Earth fault, single set
- Remote relay output
- Paralel system with mains.
- Automatic synchronising and power control system ( multi gen-set
Parallel )
- Remote annunciator panel
- Transition synchronization with mains
ENGINE
- Oil heater
- Low water level alarm
- Fuel-Water Seperator Filter
ALTERNATOR
- PMG excitation + AVR
- Main line circuit breaker
- Anti-Condensation Heater
- Over sized alternator
 
Regelsystemen: DSE 6020
1. Main status display. 
2. Display scroll button. 
3. Page(information) button. 
4. Common alarm indicator. 
5. Status LED's. 
6. Operation selecting buttons.
Apparaten
●DSE, model 6020 Auto Mains Failure control module.
●Battery charger input 198-264 volt, output 27,6 V 5 A (24 V) or 13,8 Volt 5A (12V)
●Emergency stop push button and fuses for control circuits.
Structuur en verf
●Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface. Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable and hinged panel door provides easy access to components.
Montage
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at the Gen.Set. from Alternator)
Generator regeleenheid
The DSE 6020 is a standard control module for our generator sets up to 200kVA and ıt has been designed to start and stop diesel and gas generator sets.
The DSE 6020 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant temperature running hours and battery volts.
Module monitors the mains supply and switch over to the generator when the mains power fails.
The DSE6020 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving true first up fault condition of Gen. Set failure.The LCD display indicates the fault.

Standaardfuncties
●Microprocessor controlled.
●LCD display makes information easy to read.
●4-line, 64 x 132 pixel display.
●Automatically transfers between mains (utilty) and generator power.
●Manual programming on front panel.
●User-friendly set-up and button layout.
●Remote start.
●Event logging (5)showing date and time.
●Controls: Stop/Reset, Manual, Auto, Test, Start, buttons. An additional push button next to the LCD display is used to scroll through the modules' metering displays.

Meetindicatoren
ENGINE
●Engine speed.
●Oil pressure.
●Coolant temperature.
●Run time.
●Battery volts.
●Configurable timing.

GENERATOR
●Voltage (L-L, L-N).
●Current (L1-L2-L3).
●Frequency.

MAINS
●Voltage (L-L, L-N).
●Frequency.
●Mains ready.
●Mains enabled.
●Gen. Set ready.
●Gen. Set enabled.
Beveiligingscircuits
WARNING 
●Charge failure. 
●Battery Low/High voltage. 
●Fail to stop. 
●Low /High generator voltage. 
●Under/over generator frequency. 
●Over /Under speed. 
●Low oil pressure. 
●High coolant temperature. 

SHUT DOWNS 
●Fail to start. ●Emergency stop. 
●Low oil pressure. 
●High coolant temperature. 
●Over /Under speed. 
●Under/over generator frequency. 
●Under/over generator voltage. 
●Oil pressure sensor open. 
●Coolant temperature sensor open. 

ELECTRICAL TRIP 
●Generator over current.


Optie Kenmerken
●Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
●Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
Standaarden
Elecrical Safety / EMC compatibility
●BS EN 60950 Electrical business equipment.
●BS EN 61000-6-2 EMC immunity standard.
●BS EN 61000-6-4 EMC emission standard
Elektronische acculader
● Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC.
Proline 2405 has fully output shot circuit protection and ıt can be used as a current source.
Proline 1205/2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives.
The charger is fitted with a protection diode across the output.
Connect charge fail relay coil between positive output and CF output.
They are equipped with RFI filter to reduce electrical noise radiated from the device.
Galvanically isolated input and output typically 4kV for high reliability.
Cabine: MS 60
1. Steel structures. 
2. Emergency stop push button. 
3. Control panel is mounted on the baseframe . Located at the right side of the generator set. 
4. Corrosion-resistant locks and hinges. 
5. Oil could be drained via valve and a hose 
6. Exhaust system in the canopy. 
7. Special large access doors for easy maintanance 
8. In front and back side special large access doors for easy maintanance 
9. Base frame -fuel tank. 
10. Lifting points similar to ISO container , located on each top corner of the canopy. 
11. The cap on the canopy provides easy accsess to radiator cap. 
12. Sound proofing materials 
13. Plastic air intake pockets.
Over Product
Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
Standaardfuncties
Compact footprint, low profile design. 
Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package 
Body made from steel components treated with polyester powder coating 
Fire retardant foam insulation 
Easy access to all service points 
Exhaust system inside canopy 
Large doors on each side 
Control panel viewing window in a lockable access door 
Emergency stop push button mounted on enclosure exterior 
Cooling fan and battery charging alternator fully guarded 
Fuel fill and battery can only be reached via lockable access doors. 
Lifting points on the top of canopy and base frame 
Customer options available to meet your applications needs. 
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been aproved by the notified body Szutest

Kastserie Model MS 60
Breedte mm. 1356
Lengte mm. 3934
Hoogte mm. 2156
Inhoud brandstoftank (lt.) Lt. 470