APG 80

Product: GM NG Alternator: ECP 32-3L/4 B Regelsystemen: 4520
Over Product

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Certificaten
  TS ISO 8528
  CE
  SZUTEST
  2000/14/EC
Algemene kenmerken
Modelnaam APG 80
Frequentie (HZ) 50
Brandstoftype Natural Gas
Motormerk en -model GM NG - PSI 8.8L
Alternatormerk en -model Mecc Alte - ECP 32-3L/4 B
Configuratiescherm Model 4520
Cabine AK40-APG80
3 Fasen, 50 Hz, PF 0.8
Spanning Stand-by vermogen (ESP) Prime Power (PRP) Standby Amper
kVA kW kVA kW
400/231 80 64 - 115.47
Stand-by vermogen (ESP) : Het wordt gebruikt om te voldoen aan de variabele elektrische belastingvereiste in geval van uitval van de betrouwbare netvoeding. ESP voldoet aan ISO 8528-1 Overbelasting is niet toegestaan.

Prime Power (PRP) : Wordt gedefinieerd als het continue bedrijfsvermogen onder variabele belasting. PRP voldoet aan ISO 8528-1 10% overbelasting kan elke 12 uur worden gedaan.
Motorkenmerken
Motor GM NG
Motor model PSI 8.8L
Aantal Cilinders En Gebouw 8 cylinders - V type
Boor En Slag mm 110.49 X 114.30
Totale Verplaatsing L 8.800
Aspiratie Naturally Aspirated
Compressieverhouding 10.0:1
Nominale snelheid d/dk 1500
Olie capaciteit L 8,5
Brandstoftype
Natural Gas
Governor-systeem
Electronic
Bedrijfsspanning (Vdc)
12 Vdc
Batterij en capaciteit (aantal / Ah) 1x85
Koelmethode
Water Cooled
Koelventilatorluchtstroom (m³ / min) 120
Koelvloeistofcapaciteit (alleen motor / met radiator) (lt) /25,5
Luchtfilter
Dry Type
Dynamo specificaties
Fabrikant Mecc Alte
Alternatormerk en -model ECP 32-3L/4 B
Frequentie (HZ) Hz 50
Kracht (kVA) kVA 75
Ontwerp   Brushless
Spanning V 400
Fase 3
Automatische spanningsregelaar DSR
Voltage regulatie (+/-) 1
Isolatiesysteem H
Bescherming IP23
Nominale vermogensfactor 0.8
Gewicht dynamo (Kg) 293
Koellucht (m³/min) m3 11.8
Grootte en gewicht
Open Type Droog gewicht (kg.)
(kg.)
Lengte
(mm.)
Breedte
(mm.)
Hoogte
(mm.)
Inhoud brandstoftank (lt.) (Lt.)
1120 2150 1050 1543
Cabin Group Droog gewicht (kg.)
(kg.)
Lengte
(mm.)
Breedte
(mm.)
Hoogte
(mm.)
Inhoud brandstoftank (lt.) (Lt.)
AK40-APG80
1300 3100 1050 1641 N/A
Standaardfuncties
Heavy duty, water cooled naturalgas engine 
46/50 °C ambient rated radiator with mechanical fan 
Protective grille for fan and rotating parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine jacket cooling heater 
Base frame design incorporates an integral fuel tank and anti-vibration isolators 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel belows supplied separately 
Static battery charger 
Manual for use and installation
Generator hardware-opties
ENGINE
  • Remote Radiator Cooling
  • Low Coolant level alarm
ALTERNATOR
  • Anti-Condensation heater
  • Over sized alternator
  • Main line circuit breaker
CONTROL SYSTEM
  • Remote annunciator panel
  • Uzağa alarm paneli
  • Alarm output relays
  • Earth fault, single set
  • Charging ammeter
TRANSFER ANAHTARI
  • Üç kutuplu kontaktör
  • Four Pole Contactor
VISE ACCESSORIES
  • Manual oil drain pump
  • Electrical oil drain pump
  • Enclosure: weater protective or sound attenuated
  • Duct adapter ( on radiator)
  • Inlet and outlet motorised louvers
  • Tool kit for maintenance
  • Supplied with oil and coolant - 30 °C
  • Automatic transfer switch
Regelsystemen: 4520
1 - Main Status and instrumentation display 
2 - Menu navigation buttons 
3 - Auto mode 
4 - Manual mode / start button 
5 - Reset/Stop button
Apparaten
DSE, model 4520 auto mains failure control module. 
Static battery charger. 
Emergency stop push button and fuses for control circuits.
Structuur en verf

Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface.Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable hinged panel door provides for easy component access.
Montage
Control panel is mounted generating set baseframe on robust steel stand or power module. 
Located at side of generating set with properly panel visibility.
Generator regeleenheid
The DSE 4520 conrol module is a standard addition to our generator sets between 10kva and 20kva and it has been designed to start and stop diesel generating sets that include electronic and non electronic engines. The DSE 4520 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable for controlling a standby generating set in conjunction with an automatic transfer switch. The DSE4520 also indicates operational status and fault conditions, automatically shutting down the generating set and indicating faults by means of its LCD display on the front panel.

Standaardfuncties
- *Microprocessor controlled. 
- *LCD display makes information easy to read. 
- *Front panel programming and also via PC software. 
- *Soft touch membrane keypad and two key menu navigation. 
- *Event logging (15) showing date and time. 
- *Date and time engine exercise mode and maintenance scheduler. 
- *Control buttons; stop, manuel/start, auto, menu navigation.

Meetindicatoren
ENGINE 
Engine speed 
Oil pressure 
Coolant temperature 
Run time 
Battery volts 
Engine maintenance due 
GENERATOR 
Voltage (L-L, L-N) 
Current (L1-L2-L3) 
Frequency 
kVA 
kW 
Pf 
kVAr 
kWh, kVAh, kVArh 
MAINS 
Voltage (L-L, L-N) 
Frequency
Beveiligingscircuits
WARNING 
Charge failure 
Battery Low/High voltage 
Fail to stop 
Low fuel level (opt.) 
Over current 

PRE-ALARMS 
Low oil pressure 
High engine temperature 
Over /Under speed 
Under/over generator frequency 
Under/over generator voltage 
ECU warning 

SHUT DOWNS 
Fail to start 
Emergency stop 
Low oil pressure 
High engine temperature 
Low coolant level (opt.) 
Over /Under speed 
Under/over generator frequency 
Under/over generator voltage 
Oil pressure sensor open 

ELECTRICAL TRIP 
Generator over current


Optie Kenmerken
High oil temperature shut down 
Low fuel level shut down 
Low fuel level alarm 
High fuel level alarm
Standaarden
Elecrical Safety / EMC compatibility 
BS EN 60950 Electrical business equipment 
BS EN 61000-6-2 EMC immunity standard 
BS EN 61000-6-4 EMC emission standard
Elektronische acculader
● Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficinecy. Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC. Proline 2405 has fully output shot circuit protection and ıt can be used as a current source. Proline 1205/2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives. The charger is fitted with a protection diode across the output. Connect charge fail relay coil between positive output and CF output. They are equipped with RFI filter to reduce electrical noise radiated from the device. Galvanically isolated input and output typically 4kV for high reliability.
Cabine: AK40-APG80
Standaardfuncties


Kastserie Model AK40-APG80
Breedte mm. 1050
Lengte mm. 3100
Hoogte mm. 1641
Inhoud brandstoftank (lt.) Lt. N/A